BLCTB - AGITRON 256, 0617

Product Identification

Product ID:AGITRON 256, 0617
MSDS Date:07/12/1989
FSC:6850
NIIN:00N019266
MSDS Number: BLCTB

Responsible Party
ZEP MANUFACTURING COMPANY
ATLANTA, GA 30301
US

Emergency Phone: 404-435-2973 800-424-9300(CHEMTREC)

Info Phone: 404-352-1680

Cage: 72674

Contractor
ZEP MANUFACTURING COMPANY
2015 ATLANTA, GA 30301 US

Telephone: (404) 352-1680

Cage: 72674

Ingredients

O-DICHLOROBENZENE (SARA III)

CAS: 95-50-1

RTECS: CZ4500000

Fraction By Weight: 80-90%

OSHA PEL C 50 PPM

ACGIH TLV: S, 25PPM/50 STEL9394

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


KEROSENE (PETROLEUM), HYDROTREATED; (LOW ODOR PARAFFINIC

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 5-10%

OSHA PEL 500 PPM (MFR)


HEXYLENE GLYCOL

CAS: 107-41-5

RTECS: SA0810000

Fraction By Weight: <5%

OSHA PEL C 25 PPM

ACGIH TLV: C 25 PPM; 9192


GLYCOLS, POLYETHYLENE, MONO(NONYLPHENYL) ETHER;

CAS: 9016-45-9

RTECS: MD0900000

Fraction By Weight: <5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL OF VAP CAN CAUSE CNS
DEPRESS CHARACT BY HDCH, DIZZ, NAUS, STUPOR, UNCON, & IN EXTREME
CASES, DEATH. VAP MAY ALSO PRDCE EYE, NOSE, & THROAT IRRIT. CARD
SENSIT MAY LEAD TO HEART RHYTHM DISOR DERS IN SOME INDIVIDUALS.
PROD MAY IRRIT EYES & SKIN UPON CONT. INFLAMM OF EYE IS CHARACT BY
REDNESS, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:WATERING, & ITCHING. SKIN INFLAMM IS
CHARACT BY ITCHING, SCALING, REDNESS/OCCASNLY, BLISTERING. CHRONIC
EFTS OF OVEREXP:ANIMAL STUDIES INDICATE POTNTL FOR LIVER & KIDNEY
DMG. RELEVANCE OF THE SE STUDIES/EXPOS LEVELS WHICH MIGHT PRDCE
THESE EFTS IN HUMANS HAS NOT BEEN ESTABLISHED. SKIN WHICH IS (SUPP
DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:WASH THORO W/SOAP OR MILD DETERGENT. APPLY SKIN CREAM
W/LANOLIN. GET MD IF IRRIT PERSISTS. EYES:IMMED FLUSH W/ PLENTY OF
H2O FOR @ LST 15 MINS, OCCAS LIFTING UPPER & LOWER LIDS. GET MD.
INHAL:MOV E EXPOS PERS TO FRESH AIR AT ONCE. IF BRTHG STOPS,
PERFORM ARTF RESP. GET MD IMMED. INGEST:IF SWALLOWED, DO NOT INDUCE
VOMIT. IF VOMIT OCCURS, KEEP HEAD BELOW HIP LEVEL. GET MD IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:152F,67C
Lower Limits:2.2%
Upper Limits:9.2%
Extinguishing Media:FOAM, DRY CHEMICAL, CO2
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED POSITIVE PRESSURE
SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONCENTRATED VAPOR MAY IGNITE IF EXPOSED
TO SPARK.

Accidental Release

Spill Release Procedures:IMMED ELIM ALL FLAME, IGNIT & HIGH-HEAT
SOURCES. ABSORB SPILL ON INERT ABSORB MATL. PICK UP & PLACE RESIDUE
IN CLEAN, D.O.T. SPECIFICATION CONTR FOR DISPOS. WASH AREA
THOROUGHLY WITH DETERGENT SOLN & RINSE WELL W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:COMBUST:STORE & USE AWAY FROM HEAT,
SPARKS, OPEN FLAME, OR ANY SOURCE OF IGNITION. VAPS ARE HEAVIER
THAN AIR & WILL ACCUM AT LOW POINTS.
Other Precautions:VENT SHOULD INCL FLOOR LEVEL EXHST. FIRE EXPOS DRUMS
SHOULD BE COOLED W/STREAM OF H20. KEEP PROD AWAY FROM SKIN/EYES. DO
NOT BREATH VAP. STORE TIGHTLY CLSD CNTNR IN DRY AREA @ TEMPS
BETWEEN 40-120F. K EEP OUT OF THE REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:IF VENTILATION IS INADEQUATE, WEAR A PROPERLY
FITTING NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:VENTILATION SHOULD BE EQUAL TO OUTDOORS. USE EXHAUST FANS
AND/OR EXHAUST HOOD IN ENCLOSED SPACES.
Protective Gloves:VITON GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN WHEN HANDLING
THIS MATL.
Supplemental Safety and Health
EFTS OF OVEREXP:REPEATEDLY DEFATTED BY CONTACT WITH THIS PRODUCT MAY BE
MORE SUSCEPTIBLE TO IRRITATION, INFECTION, OR DERMATITIS. WASTE
DISP METH:OR INDUSTRIAL WASTE LANDFILL. CONSULT LOCAL, STATE, AN D
FEDERAL AGENCIES FOR PROPER DISPOSAL METHOD IN YOUR AREA.

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:260F,127C
Vapor Pres:0.3MM
Spec Gravity:1.2
Evaporation Rate & Reference:0.03 (CCL4=1)
Solubility in Water:EMULSIFIES
Appearance and Odor:CLEAR, THIN, AMBER LIQUID WITH A "MOTHBALL" TYPE
ODOR.
Percent Volatiles by Volume:91

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, ALKALIES, AND OXIDIZERS.
Stability Condition to Avoid:HEAT, FLAME AND SPARK.
Hazardous Decomposition Products:CO, CO2, HYDROGEN CHLORIDE, AND SMALL
AMOUNTS OF PHOSGENE AND CHLORINE GAS.

Disposal

Waste Disposal Methods:LIQ CANT BE SENT TO LANDFILLS UNLESS SOLIDIFIED.
UNUSABLE PROD & COLLECTED, SPENT MATL MAY REQ DISPOS AS HAZ WASTE
AT PERMITTED TREATMENT/STOR/DISPOS FACILITY. SOLV WASTES MAY REQ
TREATMENT TO MEET AP PROP STD BEFORE DISPOS IN CHEM (SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.